The Z, Z2 and Z3 have a tilt sensor that measures how far you tilt the mouse, for tilt mappings and the Tilt Angles screen. Calibrating it takes the way the mouse sits on your desk as level, so tilts are measured from there.
Calibrate the tilt sensor when a tilt mapping runs while the mouse is flat, when one direction triggers much sooner than the other, or after moving to a different desk.
Calibrate
- Place the mouse flat on your desk, where and how you use it most. Make sure the desk isn't being bumped.
- Click Devices in the sidebar, then Calibrate Tilt Sensor on your mouse's card.
- Click Start Calibration, then take your hand off the mouse.
- Wait for Tilt Calibration Complete, a few seconds later, then click Finish.

While Tilt Calibration in Progress... shows, don't touch the mouse or unplug it.

Calibrating also zeroes the tilt angles where the mouse sits, so flat on your desk reads 0°.
If it fails
Tilt Calibration Failed gives the reason. Click OK, then click Calibrate Tilt Sensor to try again.
- Calibration failed: The mouse couldn't finish calibrating, most often because it moved. Keep your hand off it and the desk still, then try again.
- Calibration timed out: The mouse didn't answer. Check it is still connected, or connect it with its USB cable, then try again.
- No device connected: The mouse disconnected. Reconnect it, then try again.
Zeroing the angles without calibrating
-
Re-Zero Tilt, Re-Zero Pivot and Re-Zero Tilt & Pivot: Set the mouse's current angle as zero from any button you map them to. They are in the action library under Mouse Settings › Tilt & Pivot.
- In an output list the same output is Reset / Calibrate Tilt Angles.
- Tilt Auto-Zeroing: A profile setting in Expert View's Profile Settings. When enabled, the mouse re-zeroes its angles by itself while you move it flat on the desk.