Deep click uses force sensors in the mouse to detect how much pressure is applied. If your deep clicks are not starting at 0%, can't reach 100%, or is reaching it too soon. Then calibrating the force sensors will help.
1. Pick the button
Click Devices in the sidebar, then Calibrate Force Sensors on your mouse's card. The Force Sensor Calibration window opens.

Pick the button from the list, then click Tune/Calibrate.
-
A button that has been calibrated before offers Tune,which lets you tweak the existing calibration.
-
If the button doesn't have any calibration applied yet Calibrate will be shown instead.
-
Left Button and Left Fingertip are on every mouse.
- Right Button and Right Fingertip are listed only on the Z, Z2 and Z3.
Keyboard and joystick outputs from your mappings are turned off while the calibration window is open, so your test presses don't type or move anything. Make sure to close the dialog before returning to other applications.
2. Full Calibration
The window takes you through three steps. Follow the instruction on each.
- Zeroing: Take your hand off the mouse. After a short countdown the sensors are zeroed with nothing pressing on them.
- Click Point: Gently press the button until it just clicks, then gently release it.
- Full Press: Press the button as firmly as you comfortably can with your normal grip, then release it.

If a step fails, the window says why. Click Finish to go back to the button list, then try again.
- "Ensure all buttons are released and your hand is off the mouse" or "Failed to zero sensors" means the mouse was touched during Zeroing.
- "Incorrect button press detected" means a different button was pressed.
- "Your full press was barely harder than the click. Press harder next time." means there wasn't enough difference between the click point and full press for a good calibration.
3. Tune the curve
After the presses, the Tune step shows the button's curve: how hard you press along the bottom, and the output it gives up the side. Click and Your full press mark the two presses you just made. Press the button to try it: a dot follows your press along the curve, and the Output readout beside it shows the result.
Drag the three handles left or right to change the curve. The preview follows straight away.
-
0%: Sets how hard a press must be before output starts.
- It can sit a little before the click (at most a tenth of the way from the click to your full press), so output already shows when the button clicks. Force is reported only while the button is down.
- 40%: Changes how quickly the output builds between the start and full output.
-
100%: Sets how hard a press reaches full output.
- It can go past your full press. A press short of it then never reaches 100%.

Then click one of the buttons at the bottom of the window.
- Save: Sends the curve to the mouse and shows "Calibration Successful". Click Finish to go back to the button list and calibrate the next button.
- Reset Handles: Puts the handles back where they started.
- Redo Presses: Starts the calibration from the beginning.
- Cancel: Closes the window. The mouse keeps the calibration it had.

The middle button
The middle button has no calibration of its own. It uses the Left Fingertip or Right Fingertip calibration, whichever side you press harder, with a steeper curve: a press that would read 90% on the fingertip reads 100% on the middle button. Calibrate both fingertips to change it.